How to use it
Enter the width and depth of cut and the feed rate, then tap a material to fill a rough unit power, or type your own. Drive efficiency covers belt and gearbox losses; 80% is a common assumption for a belt-driven spindle, 90% or more for a direct drive.
The formulas
Metal removal rate Q = width × depth × feed. In inch units, power at the cut (hp) = Q (in³/min) × unit power (hp per in³/min). In metric, power (kW) = Q (cm³/min) × specific cutting force kc (N/mm²) ÷ 60,000. Motor power = power at the cut ÷ efficiency.
Rough unit powers
The material buttons use cautious rule-of-thumb figures: aluminium 0.3, brass 0.5, cast iron 0.7, mild steel 1.0, titanium 1.2, alloy steel 1.3 and stainless 1.4 hp per in³/min. In metric they become kc values by multiplying by about 2,730. Harder material, dull tools and very thin chips all need more; tool makers publish kc values for their own tools and grades.
Low spindle speeds
Many spindles only reach full power above a base speed. Below it, the power available drops roughly in proportion to speed, so a big cutter at low RPM can stall a spindle that looks big enough on paper. Check your spindle's power curve.