How to use it
Enter the material thickness, the inside bend radius, the bend angle and a K-factor. Add both flange lengths, measured to the outside of the part, to get the flat blank length. Switch units at the top.
The formulas
Bend allowance BA = angle × π ÷ 180 × (R + K × T): the arc length of the neutral axis through the bend. Outside setback OSSB = (R + T) × tan(angle ÷ 2). Bend deduction BD = 2 × OSSB − BA. Flat length = flange 1 + flange 2 − BD.
Picking a K-factor
K is where the neutral axis sits, as a fraction of the thickness from the inside face. It is never above 0.5. Air bending with a radius near the thickness is often around 0.40–0.45; tight radii and bottoming push it toward 0.33, large radii toward 0.5. The most reliable K comes from your own brake: bend a test strip, measure it, and work back from the measured allowance.
Bend angle, not included angle
The angle here is how far the sheet is bent: 90 for a right-angle bracket. If a drawing gives the included angle between flanges, subtract it from 180 first.